Torque Accuracy and Repeatability

Accuracy and repeatability are sometimes used as if they were the same, but they describe different things. Accuracy indicates how close the result is to the intended value; repeatability, how similar the results of many tightenings are to each other. A tool can repeat a wrong value very well, which is why it is set, calibrated and its capability demonstrated under defined conditions.

The difference

  • Accuracy: how close the mean of the results is to the target value or to the true value measured with a reference.
  • Repeatability: how tightly grouped the results are, regardless of where the mean falls.

A repeatable but poorly set tool always gives nearly the same torque, offset from the target; it is corrected by adjustment. A tool with a lot of scatter is not corrected by adjustment: the problem lies in the tool, the joint or the process.

How to read the catalog figure

A catalog usually states scatter as a percentage. Before comparing two figures, it helps to know:

  • How it was calculated: for example, as a multiple of the standard deviation relative to the mean.
  • Under what conditions: on what type of joint, at what part of the torque range and with how many samples.
  • With what method: ISO 5393 describes a test method for continuous-drive tools that allows comparison under defined conditions. It does not apply to impact or pulse tools.

Two figures obtained with different methods are not comparable, and neither replaces testing on the real joint.

Machine capability: Cm and Cmk

Machine capability compares the tool's scatter with the tolerance the joint requires:

  • Cm indicates how many times the tool's scatter fits within the tolerance.
  • Cmk also considers how well the mean is centered within the tolerance.

They are calculated from a series of tightenings measured with reference equipment, as described in VDI/VDE 2645 Blatt 2. The minimum acceptable value is defined by the customer or the control plan.

Tool and process

Tool capability is only one part. On the line, variation in fasteners and parts, friction, the operator and how reaction is supported all add up. That is why, in addition to the machine test, process capability is evaluated on the real joint and monitored with periodic checks.

Calibration of measuring equipment

A result is only as reliable as the equipment that measured it. Transducers, analyzers and reference torque wrenches are calibrated against standards with metrological traceability, and their certificate states the uncertainty. For hand torque tools, calibration is described in ISO 6789-2.

Sources and references

  1. ISO 5393 — Rotary tools for threaded fasteners — Performance test method
  2. VDI/VDE 2645 Blatt 2 — Machine capability test (MCT) for fastening technology
  3. ISO 6789-2 — Hand torque tools — Part 2: Requirements for calibration and determination of measurement uncertainty

Technical review: Mauricio Ramirez, Senior Electric Torque Specialist

Related TMG products and services

← Back to Torque Fundamentals