Torque Control Strategy

In torque control, the tool tightens until it reaches a target torque and stops at that moment. It is the most common strategy because it is simple to specify, measure and verify with a torque wrench. What a tightening really aims for, however, is the clamp force in the joint (the preload), and torque is an indirect way to get there. This page explains how the strategy works and what to watch so the result is reliable.

How does it work?

  1. Rundown: the fastener runs in at high speed while torque is low.
  2. Snug: the fastener head contacts the part and torque starts to rise.
  3. Final tightening: the tool slows down and keeps tightening up to the target torque.
  4. Stop and evaluation: the controller stops the motor and compares the final torque with the acceptance window (minimum and maximum) to give an OK or NG result.

Torque is not clamp force

Most of the applied torque is spent overcoming friction: in the thread and under the fastener head. Only part of it becomes preload, which is what holds the joint together. If friction changes, because of the coating, lubrication, dirt or roughness, the same torque produces a different preload.

That is why a joint's torque specification is defined together with the fastener, its coating and the part conditions. The relationship between torque and preload is determined with tests such as those described in ISO 16047, and the joint is calculated with guidelines such as VDI 2230.

Monitoring the angle

When the tool has an encoder, the controller can measure how far the fastener turned from a threshold torque to the end. That angle does not decide when to stop, but it is used to check the result: for example, an angle that is too short can indicate a double hit, and one that is too long, a stripped thread. This is called torque control with angle monitoring.

Final speed and joint type

On a hard joint, torque rises very quickly at the end. If the tool arrives at high speed, it overshoots the target before it can stop. That is why the final tightening is done at low speed, or in two steps, as explained in multi-step sequences. On a soft joint, torque rises slowly and tightening takes longer. See joints and behavior.

When does it fit?

  • Most joints where the drawing or the customer specifies a torque.
  • Processes where friction is under control: consistent fasteners and coatings, and clean parts.
  • Joints that need simple verification with a torque wrench on the part.

When preload must be more precise, or the fastener is tightened into the plastic range, the torque and angle strategy is used.

Sources and references

  1. ISO 16047 — Fasteners — Torque/clamp force testing
  2. VDI 2230 Blatt 1 — Systematic calculation of highly stressed bolted joints — Joints with one cylindrical bolt

Technical review: Mauricio Ramirez, Senior Electric Torque Specialist

Related TMG products and services

← Back to Tightening Strategies