What can be recorded?
Depending on the controller and software, a per-cycle record can include:
- OK / NG result and rejection reason.
- Final torque value and, with an encoder, angle.
- Program or PSET used, date and time.
- Fastener count per part and number of attempts.
- The full tightening curve, on systems that store it.
- Part ID, serial number or VIN, when a scanner is integrated or the PLC sends it.
Not every tool records every field. Confirm them model by model before defining the process.
Where does the torque value come from?
The torque value stored in the record can come from two sources:
- Measured by a transducer in the tool. See transducer measurement.
- Estimated from motor current. See current-based estimation.
In both cases the tightening is recorded and traceable. The difference lies in the nature of the signal, the diagnostics available and the detail of the exportable data, which depend on the specific system.
How is each tightening linked to the part?
The controller result is associated with the part through an identifier: a code read with a scanner, the serial number sent by the PLC or the VIN assigned by MES. That association can happen in the controller itself, in the station PLC or in the manufacturing system, depending on the plant architecture.
Validation and periodic verification
Recording a result does not, by itself, prove the process is capable. The station is validated on the real joint — for example, with a machine capability study — and verified with a reference analyzer as often as the control plan requires.
What to define before implementing it
- What evidence the customer requires: OK/NG only, torque and angle per cycle, or the full curve.
- How the part is identified: code, serial number or VIN, and who assigns it.
- Where data is stored and how long it must be kept.
- Which communication protocol the controller, PLC and MES will use.
Sources and references
Technical review: Mauricio Ramirez, Senior Electric Torque Specialist